Skip to content

Deck Footing Size Chart and Rule of Thumb (IRC Table R507.3.1)

By Updated 4 min read

Line drawing illustrating deck footing size chart

Quick answer

Deck footing size comes from IRC Table R507.3.1: the more deck area a post carries (its tributary area) and the weaker the soil, the bigger the footing. Under a 60 psf load on 2,000 psf soil, 40 sq ft needs a 17 inch round footing and 80 sq ft needs 24 inches. A 10 or 12 inch tube on a bell or pad gets you there.

40 sq ft, 2,000 psf soil
17 in round
80 sq ft, 2,000 psf soil
24 in round
Minimum thickness
6 in (plain concrete)

Deck footings are sized by two numbers: how much deck area each footing carries, and how much load the soil can take. The IRC turns those into a minimum footing size in Table R507.3.1. Once you know the size, the Sonotube concrete calculator tells you how much concrete it takes.

Deck footing size chart

These values are from Table R507.3.1 as published in the 2021 Washington State Residential Code, an IRC-based code, for a 60 psf live load or 70 psf ground snow load. Areas with lighter loads use another row group of the same table and get somewhat smaller footings. Your locally adopted table is the one that counts.

Tributary area 1,500 psf soil: round / square / thick 2,000 psf soil: round / square / thick 3,000 psf soil: round / square / thick
5 sq ft 8 / 7 / 6 in 8 / 7 / 6 in 8 / 7 / 6 in
20 sq ft 14 / 12 / 6 in 13 / 11 / 6 in 10 / 9 / 6 in
40 sq ft 20 / 18 / 6 in 17 / 15 / 6 in 14 / 12 / 6 in
60 sq ft 24 / 21 / 8 in 21 / 19 / 6 in 17 / 15 / 6 in
80 sq ft 28 / 25 / 9 in 24 / 21 / 8 in 20 / 18 / 6 in
100 sq ft 31 / 28 / 11 in 27 / 24 / 9 in 22 / 20 / 7 in
120 sq ft 34 / 30 / 12 in 30 / 26 / 10 in 24 / 21 / 8 in
140 sq ft 37 / 33 / 13 in 32 / 28 / 11 in 26 / 23 / 9 in
160 sq ft 40 / 35 / 15 in 34 / 30 / 12 in 28 / 25 / 9 in

Table notes: interpolation is allowed, extrapolation is not. The footing must allow complete bearing of the post. Thickness applies to plain concrete footings.

Step 1: find the tributary area

Tributary area is the part of the deck surface that rests on one footing. For a deck attached to the house with one beam near the outer edge:

  • Depth share: half the joist span from the house to the beam, plus any overhang past the beam.
  • Width share: half the beam span on each side of the post.

Example: joists span 12 ft from the house to the beam, with a 1 ft overhang. Posts are 8 ft apart. A middle post carries (12 ÷ 2 + 1) × 8 = 56 sq ft. An end post carries half the width: 7 × 4 = 28 sq ft.

Step 2: pick the soil value

Your building department sets this. Clay is weaker than sand or gravel, and the IRC lets officials assume a low presumptive value when the soil is unknown.

Step 3: read the size and match it to a tube

For the 56 sq ft post on 2,000 psf soil, interpolate between 40 sq ft (17 in) and 60 sq ft (21 in): about 20 inches round. A straight 20 inch tube works, but most builders use a 12 inch tube on a bell or pad:

Footing size needed Option Concrete per footing (3 ft tube + 1 ft bell)
18 in round 12 in tube + bell to 18 in 3.60 cu ft
20 in round 12 in tube + bell to 20 in 3.78 cu ft
22 in round 12 in tube + bell to 22 in 3.98 cu ft
24 in round 12 in tube + bell to 24 in 4.19 cu ft

A square pad works too: a 24 × 24 × 8 in pad holds 2.67 cu ft. Bells come in fixed sizes, so check what your supplier stocks and round up.

Step 4: post size and height

Table R507.4 limits post height by tributary area and post size. Under a 60 psf live load, a Douglas fir 4x4 carrying 40 sq ft may be up to 10 ft 10 in tall, while a 6x6 reaches the table’s 14 ft limit. At 120 sq ft the 4x4 drops to 4 ft 1 in and the 6x6 to 13 ft 3 in. See what size Sonotube for a 6x6 post.

Common mistakes

  • Using one footing size for every post when middle posts carry twice what end posts do.
  • Treating the tube diameter as the footing size when the table needs a wider base.
  • Skipping the soil question. Weak soil can need a footing several inches wider.

Full example: one 12 × 16 ft deck

Putting the steps together for a deck 16 ft wide, joists spanning 12 ft to one beam with a 1 ft overhang, three posts 8 ft apart, 2,000 psf soil:

Post Tributary area Footing from table Footing built as Concrete
Middle 56 sq ft about 20 in round 12 in tube, 3 ft, bell to 20 in 3.78 cu ft
End (×2) 28 sq ft about 15 in round 12 in tube, 3 ft, bell to 16 in 3.43 cu ft each

Total with 10% waste: 11.71 cu ft, which is 20 bags of 80 lb or 27 bags of 60 lb. Open this deck in the calculator.

For depth, inspection and setback rules, read deck footing requirements.

Frequently asked questions

What is the rule of thumb for deck footing size?

There is no single safe rule of thumb, because footing size depends on the deck area each post carries and on the soil. Work out the tributary area and read the size from your local version of IRC Table R507.3.1.

What size footing for a 10x12 deck?

It depends on the layout. If the deck is attached to the house with one beam and three posts, the middle post carries roughly 30 sq ft and the end posts about half that. On 2,000 psf soil the table gives about 11 inches round for the end posts and 15 inches for the middle one.

Can I use a 12 inch Sonotube for deck footings?

A straight 12 inch tube bears like a 12 inch round footing, which covers only small tributary areas. Add a bell or pad to reach the diameter the table calls for.

What soil bearing value should I use if I don't know it?

Ask your building department. The IRC lets officials assume a presumptive value for unknown soil, and many deck guides start at 1,500 psf.

Figures are typical US values for planning. Building codes, product specs and local prices vary, so confirm with your local building department, the product label and your plans or engineer. See how we write and check our guides.