Deck footings are sized by two numbers: how much deck area each footing carries, and how much load the soil can take. The IRC turns those into a minimum footing size in Table R507.3.1. Once you know the size, the Sonotube concrete calculator tells you how much concrete it takes.
Deck footing size chart
These values are from Table R507.3.1 as published in the 2021 Washington State Residential Code, an IRC-based code, for a 60 psf live load or 70 psf ground snow load. Areas with lighter loads use another row group of the same table and get somewhat smaller footings. Your locally adopted table is the one that counts.
| Tributary area | 1,500 psf soil: round / square / thick | 2,000 psf soil: round / square / thick | 3,000 psf soil: round / square / thick |
|---|---|---|---|
| 5 sq ft | 8 / 7 / 6 in | 8 / 7 / 6 in | 8 / 7 / 6 in |
| 20 sq ft | 14 / 12 / 6 in | 13 / 11 / 6 in | 10 / 9 / 6 in |
| 40 sq ft | 20 / 18 / 6 in | 17 / 15 / 6 in | 14 / 12 / 6 in |
| 60 sq ft | 24 / 21 / 8 in | 21 / 19 / 6 in | 17 / 15 / 6 in |
| 80 sq ft | 28 / 25 / 9 in | 24 / 21 / 8 in | 20 / 18 / 6 in |
| 100 sq ft | 31 / 28 / 11 in | 27 / 24 / 9 in | 22 / 20 / 7 in |
| 120 sq ft | 34 / 30 / 12 in | 30 / 26 / 10 in | 24 / 21 / 8 in |
| 140 sq ft | 37 / 33 / 13 in | 32 / 28 / 11 in | 26 / 23 / 9 in |
| 160 sq ft | 40 / 35 / 15 in | 34 / 30 / 12 in | 28 / 25 / 9 in |
Table notes: interpolation is allowed, extrapolation is not. The footing must allow complete bearing of the post. Thickness applies to plain concrete footings.
Step 1: find the tributary area
Tributary area is the part of the deck surface that rests on one footing. For a deck attached to the house with one beam near the outer edge:
- Depth share: half the joist span from the house to the beam, plus any overhang past the beam.
- Width share: half the beam span on each side of the post.
Example: joists span 12 ft from the house to the beam, with a 1 ft overhang. Posts are 8 ft apart. A middle post carries (12 ÷ 2 + 1) × 8 = 56 sq ft. An end post carries half the width: 7 × 4 = 28 sq ft.
Step 2: pick the soil value
Your building department sets this. Clay is weaker than sand or gravel, and the IRC lets officials assume a low presumptive value when the soil is unknown.
Step 3: read the size and match it to a tube
For the 56 sq ft post on 2,000 psf soil, interpolate between 40 sq ft (17 in) and 60 sq ft (21 in): about 20 inches round. A straight 20 inch tube works, but most builders use a 12 inch tube on a bell or pad:
| Footing size needed | Option | Concrete per footing (3 ft tube + 1 ft bell) |
|---|---|---|
| 18 in round | 12 in tube + bell to 18 in | 3.60 cu ft |
| 20 in round | 12 in tube + bell to 20 in | 3.78 cu ft |
| 22 in round | 12 in tube + bell to 22 in | 3.98 cu ft |
| 24 in round | 12 in tube + bell to 24 in | 4.19 cu ft |
A square pad works too: a 24 × 24 × 8 in pad holds 2.67 cu ft. Bells come in fixed sizes, so check what your supplier stocks and round up.
Step 4: post size and height
Table R507.4 limits post height by tributary area and post size. Under a 60 psf live load, a Douglas fir 4x4 carrying 40 sq ft may be up to 10 ft 10 in tall, while a 6x6 reaches the table’s 14 ft limit. At 120 sq ft the 4x4 drops to 4 ft 1 in and the 6x6 to 13 ft 3 in. See what size Sonotube for a 6x6 post.
Common mistakes
- Using one footing size for every post when middle posts carry twice what end posts do.
- Treating the tube diameter as the footing size when the table needs a wider base.
- Skipping the soil question. Weak soil can need a footing several inches wider.
Full example: one 12 × 16 ft deck
Putting the steps together for a deck 16 ft wide, joists spanning 12 ft to one beam with a 1 ft overhang, three posts 8 ft apart, 2,000 psf soil:
| Post | Tributary area | Footing from table | Footing built as | Concrete |
|---|---|---|---|---|
| Middle | 56 sq ft | about 20 in round | 12 in tube, 3 ft, bell to 20 in | 3.78 cu ft |
| End (×2) | 28 sq ft | about 15 in round | 12 in tube, 3 ft, bell to 16 in | 3.43 cu ft each |
Total with 10% waste: 11.71 cu ft, which is 20 bags of 80 lb or 27 bags of 60 lb. Open this deck in the calculator.
For depth, inspection and setback rules, read deck footing requirements.