Skip to content

Pole Barn Footing Size: Pads, Sonotubes and Depth

By Updated 5 min read

Line drawing illustrating pole barn footing size

Quick answer

Pole barn footing size is set by the load on each post and the soil, so it comes from the building's engineered plans. Common setups are a precast or poured pad under an embedded post, or a poured pier in an 18 to 24 inch form tube with a bracket on top. A 30 × 40 ft barn with 14 posts on 18 inch piers 4 ft deep takes about 4 cubic yards of concrete with waste.

Who sizes it
Engineer / plans
Common pier tube
18 to 24 in
14 piers, 18 in × 4 ft
≈3.7 cu yd

A pole barn puts the whole building on its posts, so each footing carries a share of the roof, snow and wind loads. That makes pole barn footing size an engineering number, usually printed on the plans the building kit or designer provides. This guide explains the common setups and how to count the concrete with the Sonotube concrete calculator.

Three common footing setups

Setup How it works Notes
Pad under an embedded post A precast or poured concrete pad at the bottom of the hole; the treated post stands on it and the hole is backfilled or collared Traditional post-frame method
Pad plus concrete collar Same pad, with concrete poured around the bottom of the post to resist uplift Often specified for wind uplift
Poured pier with bracket A form tube filled with concrete from the bottom of the hole to above grade, with a wet-set bracket on top Keeps the wood out of the ground

Your plans say which one, and give the pad diameter, thickness and depth.

What sets the size

  • Post load: roof span, post spacing and the snow load where you build. Heavier snow means bigger pads.
  • Uplift: wind trying to lift the roof. Collars, uplift anchors or deeper piers resist it.
  • Soil: weaker soil needs a bigger pad for the same load.
  • Frost depth: the bottom of the footing goes below it. See frost line depth.

Concrete for a 30 × 40 ft barn

Example layout: posts 8 ft apart on the 40 ft walls (6 per side) and one middle post on each 30 ft end wall, so 14 posts. Each on an 18 inch poured pier 4 ft deep.

Item Amount
One pier 7.07 cu ft
14 piers 98.96 cu ft (3.67 cu yd)
With 10% waste 108.86 cu ft (4.03 cu yd)
80 lb bags 182
Ready-mix, rounded 4.25 cu yd

At that size, a truck almost always beats bags. Open this layout in the calculator, enter your prices in step 3, and it compares bags with ready-mix including a short-load fee. Change the diameter, depth and count to match your plans.

Pad only

If your plans call for a round pad under each post instead of a full pier, enter the pad as a short tube. A 24 inch pad 8 inches thick is a 24 inch tube 0.67 ft tall: 2.09 cu ft each, or 4 bags of 80 lb. Fourteen of them with 10% waste take 32.2 cu ft, about 54 bags.

Embedded posts vs brackets on piers

Compare Embedded post on a pad Post on a bracket over a pier
Wood in the ground Yes, must be rated for ground contact No, the post starts above grade
Concrete per post A pad, plus a collar if specified A full pier from the bottom of the hole to above grade
Uplift Collars, uplift cleats or anchors Bracket and pier weight
Concrete cost Lower Higher
Replacing a post Hard Easier

The engineered plans for the building decide which one you use. Some kits are designed only for one method.

Planning the concrete

  1. Get the footing schedule from the plans: diameter, thickness or depth, and any collar.
  2. Count the posts, including door jambs and interior posts if there are any.
  3. Enter each footing type as its own row in the calculator: piers as tubes, pads as short tubes, square pads as a pad footing.
  4. Add 10% for waste. Holes for big posts are rarely neat.
  5. Compare bags and ready-mix in step 3. At pole barn volumes, ready-mix usually wins.

Ordering ready-mix for a barn

  • Tell the supplier the total in cubic yards, rounded up, and that it is for post footings.
  • Ask whether the truck can reach every hole. If not, plan a wheelbarrow crew, a buggy, or pour in sections.
  • Have every hole dug, inspected if required, and ready before the truck arrives. Waiting time is often charged.
  • Have a plan for leftover concrete, such as forms for a small pad or step.

Inspection

Many jurisdictions inspect post holes before concrete, the same as deck footings. Keep the plans on site and call for the inspection when the holes are dug to depth and any pads or forms are set.

Concrete in large tubes

Pole barn piers often use bigger tubes than decks. Per pier, no waste:

Tube Per foot 4 ft pier 80 lb bags (4 ft)
18 in 1.77 cu ft 7.07 cu ft 12
24 in 3.14 cu ft 12.57 cu ft 21
30 in 4.91 cu ft 19.63 cu ft 33

Large tubes hold a lot of concrete and push hard on their sides when full. Backfill and brace them well, and pour in lifts.

Common mistakes

  • Sizing pads from a neighbor’s barn instead of your plans. Snow load, span and soil differ from site to site.
  • Forgetting door jamb posts and interior posts when counting footings.
  • Ordering ready-mix before every hole is dug and inspected.
  • Backfilling with the clay that came out of the hole in wet areas, which holds water around the posts. Follow the plans for backfill material.

Quick answers

  • Footing size: from the engineered plans, set by post load, snow and wind loads, and soil.
  • Common pier tubes: 18 to 24 inches, larger for heavy buildings.
  • Depth: below the frost line and as deep as the plans require for uplift and side loads.
  • Concrete for 14 piers, 18 in × 4 ft: about 4 cubic yards with 10% waste, usually a ready-mix job.

For smaller buildings on piers, see concrete pier foundation.

Frequently asked questions

How big should pole barn footings be?

Follow the engineered plans for the building. Pad size depends on the post load, the snow and wind design loads and the soil. Large barns commonly use pads or piers 18 to 24 inches across or more.

How deep should pole barn posts be?

Below the frost line and deep enough to resist uplift and side loads, as the plans specify. Embedded posts are often set several feet deep.

Should pole barn posts go in concrete?

Common methods include a concrete pad under the post with a concrete or soil collar around it, or a poured pier with a bracket that keeps the wood above ground. The building's plans decide.

Is it cheaper to use ready-mix for a pole barn?

Usually, once the job passes a cubic yard or two. Fourteen 18 inch piers 4 ft deep need about 4 cubic yards with 10% waste, which is 182 bags of 80 lb mix.

Figures are typical US values for planning. Building codes, product specs and local prices vary, so confirm with your local building department, the product label and your plans or engineer. See how we write and check our guides.